BACnet MSTP to Profibus DP Gateway || BACnet MSTP to Profibus DP Conversion
ProtoConvert recommends the FieldServer gateway for your BACnet MSTP protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning. 

This gateway can read BACnet MSTP data from your BACnet MSTP devices and publish it as Profibus DP data.

It can also write to the BACnet MSTP devices.

This gateway can also do the reverse, read Profibus DP data and publish it as BACnet MSTP data.

It can also write to the Profibus DP devices.

In summary, this gateway can act as:

Client/Master on the BACnet MSTP network: Hence it is capable of reading data from the various BACnet MSTP slave devices and writing data to them if required.

Server/Slave on the BACnet MSTP network: You can use the gateway in this mode if you have a BACnet MSTP master on the network which would be reading data from the gateway.

Client/Master on the Profibus DP network: Hence it is capable of reading data from the various Profibus DP devices and writing data to them if required.

Server/Slave on the Profibus DP network: The gateway can be configured to be a server of data values, hence another Profibus DP client can read data from the gateway and write data into the gateway.

Downloads

Protocol datasheet 

BACnet

Profibus DP Master

Profibus DP Slave

Manuals

BACnet MSTP

Profibus DP Master

Profibus DP Slave

Hardware gateways

FSB3510 datasheet

 

Question/Purchase



FieldServer Gateways for BACnet MSTP - Profibus DP

This table lists the different FieldServer hardware platforms which support BACnet MSTP - Profibus DP conversion. You can make a choice depending on the number of serial/Ethernet /lonworks ports you require and the point count capacity being considered.

We will help choose the right gateway model for you. Please contact us with your detailed requirement.

Device Type 

Serial Ports

Lonworks Ports

Ethernet Ports

Base Point Count Capacity

Extended Point Count Capacity

FS-B3510

2xRS-485

2xRS-232

1xRS-232 System Port

1

2

 1000

10000

 How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page