Metasys N2 to Omron FINS Gateway || Metasys N2 to Omron FINS Conversion
ProtoConvert recommends the FieldServer gateway for your Metasys N2 protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning. 

This gateway can read Omron FINS data and publish it as Metasys N2 data.

It can also write to the Omron FINS devices.

In summary, this gateway can act as:

Client/Master on the Metasys N2 network: Hence it is capable of reading data from the various Metasys N2 slave devices and writing data to them if required.

Server/Slave on the Metasys N2 network: You can use the gateway in this mode if you have a Metasys N2 master on the network which would be reading data from the gateway.

Client/Master on the Omron FINS network: Hence it is capable of reading data from the various Omron FINS devices and writing data to them if required.

Server/Slave on the Omron FINS network: Various Omron FINS devices can read/write on the gateway.

 
Downloads

Protocol Datasheets
Metasys N2

Omron FINS

Hardware Datasheets
QuickServer

FS-3510

Configuration Manuals
  Metasys N2
 
Omron FINS


FieldServer Gateways for Metasys N2 - Omron FINS:

This table lists the different FieldServer hardware platforms which support Metasys N2 - Omron FINS conversion. You can make a choice depending on the number of serial/Ethernet /lonworks ports you require and the point count capacity being considered.

We will help choose the right gateway model for you. Please contact us with your detailed requirement.

Device Type 

Serial Ports

Lonworks Ports

Ethernet Ports

Base Point Count Capacity

Extended Point Count Capacity

 Enhanced QuickServer 

2

 1

500 

1000

FS-B3510

2xRS-485

2xRS-232

1xRS-232 System Port

1

2

 1000

10000

 How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page