CAN BUS Fiber Optic Converter

HFD-FO-CAN DIN Rail CAN Fiber optic Converter

Transmission rate:

The HFD-FO-CAN support all the transmission speeds (transmission rates):0-1Mbps.The transmission rate is set automatically as soon as the canbus HFD-FO-CAN receives a frame. The setting or adjustment is dependent on the transmission rate. Depending on the HFD-FO-CAN Settings in automatically mode,

Segment monitoring at the optical line

Each receiver monitors the optical line port connected to it for receive frames and status. If faulty frames are received by the receiver, or no single for longer than the maximum permitted time, forwarding of the received signals is blocked until the port status is ok ,frames can be received again correctly.

Network Topologies

The following network topologies can be realized with the HFD-FO-CAN:

  • Point-to-point topologies
  • Multi-drop Bus

Fiber Mode: Single mode or Multi Mode

Technical Data

Voltage/power supply

5V/12V/24V,Dual Power Supply

Operating voltage

9 V to 30 V DC, typ. 24 V,

Current consumption

typ. 80 mA@24V

Output voltage/current (Pin 6 Sub-D socket)

5 V +5%,–10%/ 90 mA

Signaling contact Signal transmission

Max .switch DC24V@2A or AC125@0.2A

Transmission rate

0-1Mbps

Setting transmission rate

Automatic or Switch setting

Bit error rate

< 10-9

Electrical port

Terminal or DB9

Input/output signal

CAN2.0A, CAN2.0B,ISO-11898

PIN assignment

 

Optical ports

1 or 2 (2 as standard)

Wavelength

SM:1310 nm, MM:850nm

optical power:– in glass fiber 9/125um

– in glass fiber G 62.5/125

-9dBm  –  -18 dBm

-13 dBm –  -20 dBm

Receiver sensitivity

-34dBm

Transmission distance:with glass fiber 9/125um

with glass fiber G 62,5/125

0 – 20,000 m (0.3 dB/km)

0 – 3,000 m  (2.0 dB/km)

Connector

ST/FC/SC

Others

 

Ambient temperature

-30 °C to +70 °C

Storage temperature

–40 °C to +85 °C

Relative humidity

<95 %, non-condensing

Protection class

IP 30

Dimensions (W x H x D)

40 x 120 x 92mm

Housing material/Color

Die-cast zinc/Black

Weight

approx. 600 g

Electromagnetic compatibility (EMC)

  • Limit class B (EN 55022)
  • EN 61000-4-2
  • EN 61000-4-3)
  • Burst: On power supply lines and shielded RS 485 bus lines: ±2 kV (EN 61000-4-4)
  • Surge: Power lines: ±1 kV symmetrical,Shielded RS 485 lines: ±2 kV asymmetrical (EN 61000-4-5)
  • Application: The HFD-FO-CAN converter can be used in fire alarm system,radar system,security,industrial automation,solar palnt and other industrial fields.

Model Selection:

Model Number

Description

Fiber No.

Fiber Mode

Fiber Connector

HFD-FO-CAN-P1M

Point to point Link,Single Fiber(BI-DI), 2km

1

Multi Mode

ST/SC/FC

HFD-FO-CAN-P2M

Point to point Link,Dual Fiber, 2km

2

Multi Mode

ST/SC/FC

HFD-FO-CAN-P1S

Point to point Link,Single Fiber(BI-DI), 20km

1

Single Mode

ST/SC/FC

HFD-FO-CAN-P2S

Point to point Link,Dual Fiber, 20km

2

Single Mode

ST/SC/FC


EnquiryForm
*Name :  
*Email Address :    
Phone Number :
Company Name :
*Message :