HFD-FO-CAN Multi-drop CAN BUS Fiber Media Converter
Transmission rate:
The HFD-FO-CAN support all the transmission speeds (transmission rates):0-1Mbps.The transmission rate is set automatically as soon as the HFD-FO-CAN receives a frame. The setting or adjustment is dependent on the transmission rate. Depending on the HFD-FO-CAN Settings in automatically mode,
Segment monitoring at the optical line
Each receiver monitors the optical line port connected to it for receive frames and status. If faulty frames are received by the receiver, or no single for longer than the maximum permitted time, forwarding of the received signals is blocked until the port status is OK,frames can be received again correctly.
Network Topology: Multi-drop Bus
Technical Data
|
Voltage/power supply
|
5V/12V/24V DC,Dual Power Supply
|
Operating voltage
|
9 V to 30 V DC, typ. 24 V,
|
Current consumption
|
typ. 80 mA@24V
|
Output voltage/current (Pin 6 Sub-D socket)
|
5 V +5%,–10%/ 90 mA
|
Signaling contact Signal transmission
|
Max .switch DC24V@2A or AC125@0.2A
|
Transmission rate
|
0-1Mbps
|
Setting transmission rate
|
Automatic or Switch setting
|
Bit error rate
|
< 10-9
|
Electrical port
|
Terminal or DB9
|
Input/output signal
|
CAN2.0A, CAN2.0B,ISO-11898
|
PIN assignment
|
|
Optical ports
|
2 or 4 (4 as standard)
|
Wavelength
|
SM:1310 nm, MM:850 nm
|
optical power:– in glass fiber 9/125um
– in glass fiber G 62.5/125
|
-9dBm – -18 dBm
-13 dBm – -20 dBm
|
Receiver sensitivity
|
-34dBm
|
Transmission distance:with glass fiber 9/125um
with glass fiber G 62,5/125
|
0 – 20,000 m (0.3 dB/km)
0 – 3,000 m (2.0 dB/km)
|
Connector
|
ST/FC/SC
|
Others
|
|
Ambient temperature
|
-30 °C to +70 °C
|
Storage temperature
|
–40 °C to +85 °C
|
Relative humidity
|
<95 %, non-condensing
|
Protection class
|
IP 30
|
Dimensions (W x H x D)
|
40 x 120 x 92 mm
|
Housing material/Color
|
Die-cast zinc/Black
|
Weight
|
approx. 650 g
|
Electromagnetic compatibility (EMC)
- Limit class B (EN 55022)
- EN 61000-4-2
- EN 61000-4-3)
- Burst:On power supply lines and shielded RS 485 bus lines: ±2 kV (EN 61000-4-4)
- Surge:Power lines: ±1 kV symmetrical,Shielded RS 485 lines: ±2 kV asymmetrical (EN 61000-4-5)
- Application: The HFD-FO-CAN converter can be used in fire alarm system,radar system,security,industrial automation,solar palnt and other industrial fields.
Model Selection:
Model Number
|
Description
|
Fiber No.
|
Fiber Mode
|
Fiber Connector
|
HFD-FO-CAN-M2M
|
Multi point Bus Link,Dual Fiber(BI-DI), 2km
|
2
|
Multi Mode
|
ST/SC/FC
|
HFD-FO-CAN-M4M
|
Multi point Bus Link,4 Fiber, 2km
|
4
|
Multi Mode
|
ST/SC/FC
|
HFD-FO-CAN-M2S
|
Multi point Bus Link,Dual Fiber(BI-DI), 20km
|
2
|
Single Mode
|
ST/SC/FC
|
HFD-FO-CAN-M4S
|
Multi point Bus Link,4 Fiber, 20km
|
4
|
Single Mode
|
ST/SC/FC
|