KNX to Notifier 3030 Gateway || KNX to Notifier 3030 Conversion
ProtoConvert recommends the FieldServer gateway for your KNX protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning. 

This gateway can read KNX data and publish it as KNX data.

It can also write to the Notifier 3030 devices.

In summary, this gateway can act as:

Client/Master on the KNX network: Hence it is capable of reading data from the various KNX devices and writing data to them if required.

Server/Slave on the KNX network: You can use the gateway in this mode if you have a BACnet KNX master on the network which would be reading data from the gateway.

Client/Master on the Notifier 3030 network: Hence it is capable of reading data from the various Notifier 3030 devices and writing data to them if required.

 
 Downloads

Protocol Datasheets
KNX
Notifier 3030

Hardware Datasheets
QuickServer
FS-B3510

Configuration Manuals
 KNX
Notifier 3030

 


FieldServer Gateways for KNX - Notifier 3030:

This table lists the different FieldServer hardware platforms which support KNX - Notifier 3030 conversion. You can make a choice depending on the number of serial/Ethernet /lonworks ports you require and the point count capacity being considered.

We will help choose the right gateway model for you. Please contact us with your detailed requirement.

Device Type 

KNX Port 

Serial Ports

Lonworks Ports

Ethernet Ports

Base Point Count Capacity

Extended Point Count Capacity

 Enhanced Quick Server

 1

1xRS485 or RS232 

-

1

500

1000

 Enhanced Quick Server Lonworks

 1

-

 1

500 

1000

 How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page