BACnet MSTP to DNP3 Serial Gateway | | DNP3 Serial to BACnet MSTP Protocol Converter

 ProtoConvert recommends the FieldServer gateways for your BACnet protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning.

This gateway can read BACnet data from your BACnet MSTP devices and publish it as DNP3 Serial data.

It can also write to the BACnet MSTP devices.

This gateway can also do the reverse, read DNP3 Serial data and publish it as BACnet MSTP data.

It can also write to the DNP3 Serial devices.

In summary, this gateway can act as:

Client/Master on the BACnet MSTP network: Hence it is capable of reading data from the various BACnet slave devices and writing data to them if required.

Server/Slave on the BACnet MSTP network: You can use the gateway in this mode if you have a BACnet MSTP master on the network which would be reading data from the gateway.

Client/Master on the DNP3 Serial network: Hence it is capable of reading data from the various DNP3 Serial devices and writing data to them if required.

Server/Slave on the DNP3 Serial network: The gateway can be configured to be a server of data values, hence another DNP3 Serial client can read data from the gateway and write data into the gateway.


Downloads

Protocol DataSheets

BACnet MSTP

DNP3 Serial

Hardware datasheets

Enhanced QuickServer

FS-B3510

Reference Manuals

BACnet MSTP

DNP3 Serial

FieldServer Configuration manual

Question/Purchase

FieldServer Gateways for BACnet MSTP - DNP3 Serial:

This table lists the different FieldServer hadware platforms which support BACnet MSTP - DNP3 Serial conversion. You can make a choice depending on the number of serial/ethernet /lonworks ports you require and the point count capacity being considered.

We will help choose the right gateway model for you. Please contact us with your detailed requirement.

Device Type
Serial Ports
Lonworks Ports
Ethernet Ports
Base Point Count Capacity
Extended Point Count Capacity
 Enhanced QuickServer

1xRS485

1xRS485 or RS232 

- 1 500 1000
 Enhanced QuickServer Lonworks
1xRS485 or RS232
1
 1 500
1000
FS-B3510

2xRS-485

2xRS-232

1xRS-232 System Port

1 2  1000 10000

 

How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not  have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page