Modbus TCP to MBus Gateway || Modbus TCP to MBus Conversion
ProtoConvert recommends the FieldServer gateway for your Modbus TCP protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning. 
 
This gateway can read MBus data from your MBus devices and publish it as Modbus TCP data.

It can also write to the MBus devices.

This gateway can also do the reverse, read Modbus TCP data and publish it as MBus data.

It can also write to the Modbus TCP devices.

In summary, this gateway can act as:

Client/Master on the MBus network: Hence it is capable of reading data from the various MBus slave devices and writing data to them if required.

Server/Slave on the MBus network: You can use the gateway in this mode if you have an MBus master on the network which would be reading data from the gateway.

Client/Master on Modbus TCP the network: Hence it is capable of reading data from the various MBus devices and writing data to them if required.

Server/Slave on the Modbus TCP network: The gateway can be configured to be a server of data values, hence another Modbus TCP client can read data from the gateway and write data into the gateway.

 
Downloads

Protocol Datasheets

                               MBus

Modbus TCP


Hardware Datasheets


                    QuickServer


Configuration Manuals

                               MBus

                  Modbus TCP
 

Question/Purchase


FieldServer Gateways for Modbus TCP - MBus:

This table lists the different FieldServer hardware platforms which support Modbus TCP - MBus conversion. You can make a choice depending on the number of serial/Ethernet /lonworks ports you require and the point count capacity being considered.

We will help choose the right gateway model for you. Please contact us with your detailed requirement.

Device Type 

Serial Ports

M-Bus Port

Ethernet Ports

Base Point Count Capacity

Extended Point Count Capacity

 QuickServer

1

1

1

250

1000

 Enhanced QuickServer 

1

1

 1

500 

1000

 How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page